B2bmart360India's largest online marketplace, B2bmart 360 connects manufacturers, exporters, distributors & suppliers for seamless trade. Reliable, transparent platformhttps://www.b2bmart360.com/s/645a2cfc40fed60b90247247/66066d164cf03f27fbe4f178/b2bmart360-logo-480x480.jpeg
Unit No. 458, Plot No. E-5, Aggarwal Metro Height NSP, Pitampura-110034IN
B2bmart360
Unit No. 458, Plot No. E-5, Aggarwal Metro Height NSP, Pitampura, IN
+918375098857https://www.b2bmart360.com/s/645a2cfc40fed60b90247247/66066d164cf03f27fbe4f178/b2bmart360-logo-480x480.jpeg"[email protected]
661e08289b1356ed863fd8b6Yonker Patient Monitor YK-M8Yonker Patient Monitor YK-M8
Display Size 8" inch
Brand Yonker
Model YK-M8
Parameters Measured ECG, RESP, Temperature, SPO2, NIBP
Is It Washable NO
Suitable For Pediatric, Adult, Neonatal
Waveform of Respiration
ST Segment Detection analysis, pace-maker
Operation Mode Manual, Auto
No of Leads in ECG 5
Pulse Rate Range 30-250 bpm
12 Lead interpretation of ECG Yes
Number of leads analyzed for ECG in single time 3
Arrhythmia detection Yes
Respiration Range 7-120 Bpm
Display waveform of Respiration Yes
SPO2 Measurement Technique Nellcor
SPO2 Measurement Range 0-100%
Type of SPO2 probe Reusable
NIBP Measurement Technique Step Deflation Oscillometric
NIBP Measurement range 10-270 mmHg
NIBP Cuff Supplied Adult
Supplied Temperature Probe Skin
Temperature probe type Reusable
Systolic BP - low and high alarm Yes
Diastolic BP - low and high alarm Yes
Mean BP - low and high alarm Yes
Heart rate - low and high alarm Yes
SPO2 - low and high alarm Yes
Respiratory rate - low and high alarm Yes
Temperature -low and high alarm Yes
Cuff leakage alarm Yes
Cuff disconnect alarm Yes
Low battery voltage indication Yes
Sensor/ wire/probe disconnection alarm Yes
Adjustable Alarm Volume Yes
Type of alarm Audio
Suspension of Alarm Yes
Ethernet port Yes
USB port Yes
Central Patient Monitoring Station Connectivity Yes
Input Voltage 220-240 V
Type of Battery backup Lithium Ion
Wall mount availability Yes
Weight 3.4 kg
Is It Portable YES


Display 8*real color LED screen Environment Operating environment: Temperature: 0 ~ 40 C Humidity: § 85 % Pressure'' 86.0 kPa - 106.0kPa Transport and Storage environment: Temperature: -20 - 55 C Humidity: § 93 % Pressure: 86.0 kPa - 106.0kPa Power Requirements AC: 100 - 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm Dimension and Weight Equipment: 210mm × 85mm ×180mm; 1.40 kg Package: 250mm x175mm x 240mm; 3.4 kg Date Storage Trend diagram/table: 720h NIBP review: 10000 events Wave review: 12h Alarm review: 200 alarm events Support drug concentration titration analysis ECG 5 Leads: RA, LA, LL, RL, V Lead mode: I, II, I, AVR, AVL, AVF, V Gain: × 1.25mm/mV.2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error ≤ 5%) Sweep speed: 6.25mm/s. 12.5mm/s.25mm/s, 50mm/s (error ≤ + 10%) Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 - 40 Hz Diagnostic 0.05 ~ 130 Hz Sensitivity: >200 p V P-P CMRR: ≥ 112dB Differential Input Impedance: >5M ohm Electrode Offset Potential: +300mV Polarization Voltage: 2 + 500mV Input Impedance: ≥ 5 M Calibration Voltage: 1mV + 5% ST Segment ST Segment Range: -2.0mV - +2.0mV Accuracy: 0.02mV NIBP Method: Oscillometry Measure mode: Manual, Auto, STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40 - 240bpm Measure < alarm range'' Adult SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric SYS 40 ~ 220mmHg DIA 10 - 160mmHg MEAN 20 ~ 170mmHg Neonatal SYS 40 - 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg Static pressure measurement Range: 0 ~ 300mmHg Accuracy: ‡ 3mmHg Resolution: 1mmHg Accuracy: Max. Mean Error: + 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg SpOz Measurement range: 0 - 100% Resolution: Accuracy: 70% ~ 100% ‡ 2% 40% ~ 69% ‡ 3% 1% Pulse Rate Measure/alarm range: 20 - 300bpm Resolution: 1bpm Accuracy: + 3bpm RESP Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3 0 Base Impedance range: 200 02 - 4000 Bandwidth: 0.3 ~ 2.5Hz Gain: × 0.25, × 0.5, × 1, × 2, × 4 Resp rate: Measurement Range Adult 0 ~ 120BrPM Neonatal/Pediatric 0 - 150BrPM Resolution: 1BrPM Accuracy: 7 ~ 150BrPM ( * 2BrPM) 0 ~ 6BrPM (unspecified) Apnea Alarm: 10 ~ 40s TEMP Channel Measure & alarm range: 0 - 50 C Resolution: 0.1 C Accuracy (no sensor): +0.1 C (0-50 C) Standard accessories • NIBP cuff & tube • ECG cable & electrodes • SpO2 sensor • TEMP probe • Lithium-ion battery • Power cable • Operator''s manual Optional accessories • Touch screen • Trolley bracket • Hanging bracket • Monitor recorder • Vehicle-mounted powe

SKU-H93AOULKY6PJ
INR22500In Stock
11

Yonker Patient Monitor YK-M8

₹22,500

Related Products