Display Size | 8" inch |
Brand | Yonker |
Model | YK-M8 |
Parameters Measured | ECG, RESP, Temperature, SPO2, NIBP |
Is It Washable | NO |
Suitable For | Pediatric, Adult, Neonatal |
Waveform | of Respiration |
ST Segment Detection | analysis, pace-maker |
Operation Mode | Manual, Auto |
No of Leads in ECG | 5 |
Pulse Rate Range | 30-250 bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 3 |
Arrhythmia detection | Yes |
Respiration Range | 7-120 Bpm |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | Nellcor |
SPO2 Measurement Range | 0-100% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Suspension of Alarm | Yes |
Ethernet port | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Input Voltage | 220-240 V |
Type of Battery backup | Lithium Ion |
Wall mount availability | Yes |
Weight | 3.4 kg |
Is It Portable | YES |
Display 8*real color LED screen Environment Operating environment: Temperature: 0 ~ 40 C Humidity: § 85 % Pressure'' 86.0 kPa - 106.0kPa Transport and Storage environment: Temperature: -20 - 55 C Humidity: § 93 % Pressure: 86.0 kPa - 106.0kPa Power Requirements AC: 100 - 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm Dimension and Weight Equipment: 210mm × 85mm ×180mm; 1.40 kg Package: 250mm x175mm x 240mm; 3.4 kg Date Storage Trend diagram/table: 720h NIBP review: 10000 events Wave review: 12h Alarm review: 200 alarm events Support drug concentration titration analysis ECG 5 Leads: RA, LA, LL, RL, V Lead mode: I, II, I, AVR, AVL, AVF, V Gain: × 1.25mm/mV.2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error ≤ 5%) Sweep speed: 6.25mm/s. 12.5mm/s.25mm/s, 50mm/s (error ≤ + 10%) Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 - 40 Hz Diagnostic 0.05 ~ 130 Hz Sensitivity: >200 p V P-P CMRR: ≥ 112dB Differential Input Impedance: >5M ohm Electrode Offset Potential: +300mV Polarization Voltage: 2 + 500mV Input Impedance: ≥ 5 M Calibration Voltage: 1mV + 5% ST Segment ST Segment Range: -2.0mV - +2.0mV Accuracy: 0.02mV NIBP Method: Oscillometry Measure mode: Manual, Auto, STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40 - 240bpm Measure < alarm range'' Adult SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric SYS 40 ~ 220mmHg DIA 10 - 160mmHg MEAN 20 ~ 170mmHg Neonatal SYS 40 - 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg Static pressure measurement Range: 0 ~ 300mmHg Accuracy: ‡ 3mmHg Resolution: 1mmHg Accuracy: Max. Mean Error: + 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg SpOz Measurement range: 0 - 100% Resolution: Accuracy: 70% ~ 100% ‡ 2% 40% ~ 69% ‡ 3% 1% Pulse Rate Measure/alarm range: 20 - 300bpm Resolution: 1bpm Accuracy: + 3bpm RESP Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3 0 Base Impedance range: 200 02 - 4000 Bandwidth: 0.3 ~ 2.5Hz Gain: × 0.25, × 0.5, × 1, × 2, × 4 Resp rate: Measurement Range Adult 0 ~ 120BrPM Neonatal/Pediatric 0 - 150BrPM Resolution: 1BrPM Accuracy: 7 ~ 150BrPM ( * 2BrPM) 0 ~ 6BrPM (unspecified) Apnea Alarm: 10 ~ 40s TEMP Channel Measure & alarm range: 0 - 50 C Resolution: 0.1 C Accuracy (no sensor): +0.1 C (0-50 C) Standard accessories • NIBP cuff & tube • ECG cable & electrodes • SpO2 sensor • TEMP probe • Lithium-ion battery • Power cable • Operator''s manual Optional accessories • Touch screen • Trolley bracket • Hanging bracket • Monitor recorder • Vehicle-mounted powe
Display Size | 8" inch |
Brand | Yonker |
Model | YK-M8 |
Parameters Measured | ECG, RESP, Temperature, SPO2, NIBP |
Is It Washable | NO |
Suitable For | Pediatric, Adult, Neonatal |
Waveform | of Respiration |
ST Segment Detection | analysis, pace-maker |
Operation Mode | Manual, Auto |
No of Leads in ECG | 5 |
Pulse Rate Range | 30-250 bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 3 |
Arrhythmia detection | Yes |
Respiration Range | 7-120 Bpm |
Display waveform of Respiration | Yes |
SPO2 Measurement Technique | Nellcor |
SPO2 Measurement Range | 0-100% |
Type of SPO2 probe | Reusable |
NIBP Measurement Technique | Step Deflation Oscillometric |
NIBP Measurement range | 10-270 mmHg |
NIBP Cuff Supplied | Adult |
Supplied Temperature Probe | Skin |
Temperature probe type | Reusable |
Systolic BP - low and high alarm | Yes |
Diastolic BP - low and high alarm | Yes |
Mean BP - low and high alarm | Yes |
Heart rate - low and high alarm | Yes |
SPO2 - low and high alarm | Yes |
Respiratory rate - low and high alarm | Yes |
Temperature -low and high alarm | Yes |
Cuff leakage alarm | Yes |
Cuff disconnect alarm | Yes |
Low battery voltage indication | Yes |
Sensor/ wire/probe disconnection alarm | Yes |
Adjustable Alarm Volume | Yes |
Type of alarm | Audio |
Suspension of Alarm | Yes |
Ethernet port | Yes |
USB port | Yes |
Central Patient Monitoring Station Connectivity | Yes |
Input Voltage | 220-240 V |
Type of Battery backup | Lithium Ion |
Wall mount availability | Yes |
Weight | 3.4 kg |
Is It Portable | YES |
Display 8*real color LED screen Environment Operating environment: Temperature: 0 ~ 40 C Humidity: § 85 % Pressure'' 86.0 kPa - 106.0kPa Transport and Storage environment: Temperature: -20 - 55 C Humidity: § 93 % Pressure: 86.0 kPa - 106.0kPa Power Requirements AC: 100 - 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm Dimension and Weight Equipment: 210mm × 85mm ×180mm; 1.40 kg Package: 250mm x175mm x 240mm; 3.4 kg Date Storage Trend diagram/table: 720h NIBP review: 10000 events Wave review: 12h Alarm review: 200 alarm events Support drug concentration titration analysis ECG 5 Leads: RA, LA, LL, RL, V Lead mode: I, II, I, AVR, AVL, AVF, V Gain: × 1.25mm/mV.2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error ≤ 5%) Sweep speed: 6.25mm/s. 12.5mm/s.25mm/s, 50mm/s (error ≤ + 10%) Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 - 40 Hz Diagnostic 0.05 ~ 130 Hz Sensitivity: >200 p V P-P CMRR: ≥ 112dB Differential Input Impedance: >5M ohm Electrode Offset Potential: +300mV Polarization Voltage: 2 + 500mV Input Impedance: ≥ 5 M Calibration Voltage: 1mV + 5% ST Segment ST Segment Range: -2.0mV - +2.0mV Accuracy: 0.02mV NIBP Method: Oscillometry Measure mode: Manual, Auto, STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40 - 240bpm Measure < alarm range'' Adult SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric SYS 40 ~ 220mmHg DIA 10 - 160mmHg MEAN 20 ~ 170mmHg Neonatal SYS 40 - 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg Static pressure measurement Range: 0 ~ 300mmHg Accuracy: ‡ 3mmHg Resolution: 1mmHg Accuracy: Max. Mean Error: + 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg SpOz Measurement range: 0 - 100% Resolution: Accuracy: 70% ~ 100% ‡ 2% 40% ~ 69% ‡ 3% 1% Pulse Rate Measure/alarm range: 20 - 300bpm Resolution: 1bpm Accuracy: + 3bpm RESP Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3 0 Base Impedance range: 200 02 - 4000 Bandwidth: 0.3 ~ 2.5Hz Gain: × 0.25, × 0.5, × 1, × 2, × 4 Resp rate: Measurement Range Adult 0 ~ 120BrPM Neonatal/Pediatric 0 - 150BrPM Resolution: 1BrPM Accuracy: 7 ~ 150BrPM ( * 2BrPM) 0 ~ 6BrPM (unspecified) Apnea Alarm: 10 ~ 40s TEMP Channel Measure & alarm range: 0 - 50 C Resolution: 0.1 C Accuracy (no sensor): +0.1 C (0-50 C) Standard accessories • NIBP cuff & tube • ECG cable & electrodes • SpO2 sensor • TEMP probe • Lithium-ion battery • Power cable • Operator''s manual Optional accessories • Touch screen • Trolley bracket • Hanging bracket • Monitor recorder • Vehicle-mounted powe