₹44,500
₹21,800
₹25,000
₹25,000
₹44,500
₹21,800
₹25,000
₹25,000
Model Name/Number | PW-01 |
Brand | VDBM |
Type Of Equipment | Patient Warmer Systems |
Usage/Application | Hospital |
Clinical Area | Gynecology,OT,ICU |
Diameter | 600 x 350 x 2O MM |
Filter Type | WARM BLANKET |
Leakage Current | the leakage current that flows through a patient connected to an applied part or parts |
Length | full body, Upper body, lower body peadiatric, arm & shoulder & leg |
Product Type | Patient Warming System |
Material | Plastic |
Trademark | WarmTouch |
Preventing inadvertent perioperative hypothermia helps to reduce surgical site infections, the length of hospital stays and the costs per patient. The MedkonWarming Unit is a Forced Air Warming device which enables safe, comfortable and smart management of patient temperature to achieve normothermia. MedkonWarming Blankets are adaptable to most surgical cases, safe and comfortable for the patient and a smart system for healthcare professionals. Medkon Warming Blankets are designed in order to deliver an even distribution of heat throughout the entire blanket via controlled diffusion. Additional features such as the size, the tuck-in flaps and the attuned blower-blanket design make sure the blankets drape perfectly around your patient. It creates a cocoon of warmth, resulting in the maximal heat transfer towards the patient which improves your patient ’s outcome through effective patient warming.
CONTROLLED DIFFUSION
Key Features: • Optimal heat transfer & distribution towards patient • No floating • No disruption of airflow in the surrounding environment • No need for cotton linens The controlled diffusion of air combines a high-volume blower with a low-pressure blanket. The warm air of the high-volume blower is evenly distributed in thewarming blanket due to the aerodynamic attuned design of the warming blankets. The warm air is diffused - quietly and evenly - through the specially designed (permeable) material of the Medkon Warming Blankets on your patient
This technology eliminates individual, high-pressure jets of air that can blow on patients’ skin and cause the blanket to float. The disposable blanket stays in position, keeping warm air on the patient. As a result, there is no disruption of air flow in the surrounding environment and no cooling effect created by wind chill. There is no need to add cotton linens or other drapes to position the Forced Air Warming blankets
The unique Medkon Premium Blankets have an insulat ing top layer. It increases the warming capacit y with at least 10% by reducing radiant heat loss. The Premium Blankets can be used: • Passively: for the pre- and postoperative phase (patient holds the heat during transit periods when not connected to the blower) • Actively: For the pre- and postoperative phase and during surgery
The Mdekon Forced Air Warming unit complies with the latest market expectations. It allows therapy to start within 30 seconds and is comfortable to handle. The warming unit is lightweight, easy to clean and made of impact resistant material. Improve patient outcome through safe, comfortable and smart patient warming. “Medkon Forced Air Warming solution offers a high-quality range of dedicated products to optimise patient warming throughout the entire perioperative process.”
Item Category Dimensions 250mm*300mm*340mm(L×W×H)(not including extrusions) Weight ~5.5kg Wind Force Accuracy:±10 m3/h Level 0: 15 m3/h Level 1: 30 m3/h Level 2: 45 m3/h Level 3:60 m3/h Level 4: 70 m3/h Level 5:85 m3/h Maximum Output Pressure >2600Pa Temperature Range 33℃ to 43℃,at 0.5℃ increments;accuracy±1.5℃ Modes of Operation Natural wind mode、Warming mode Alarms Overheat alarm, Temperature control alarm, High temperature alarm, low temperature alarm, Heater error alarm, Fan error alarm, temperature sensor alarm Power Supply a.c.220V,50Hz,Power: 1800VA(Max.) Safety Class Class I Type BF, IPX1 (Anti dripping sealing equipment) Normal Working Conditions Temperature Humidity Atmospheric Pressure +10℃ to +40℃ 30% to 75% 700hPa to 1060hPa Components Upper case, lower case, fan, air tube, filter, control panel, operation pane
Model Name/Number | PW-01 |
Brand | VDBM |
Type Of Equipment | Patient Warmer Systems |
Usage/Application | Hospital |
Clinical Area | Gynecology,OT,ICU |
Diameter | 600 x 350 x 2O MM |
Filter Type | WARM BLANKET |
Leakage Current | the leakage current that flows through a patient connected to an applied part or parts |
Length | full body, Upper body, lower body peadiatric, arm & shoulder & leg |
Product Type | Patient Warming System |
Material | Plastic |
Trademark | WarmTouch |
Preventing inadvertent perioperative hypothermia helps to reduce surgical site infections, the length of hospital stays and the costs per patient. The MedkonWarming Unit is a Forced Air Warming device which enables safe, comfortable and smart management of patient temperature to achieve normothermia. MedkonWarming Blankets are adaptable to most surgical cases, safe and comfortable for the patient and a smart system for healthcare professionals. Medkon Warming Blankets are designed in order to deliver an even distribution of heat throughout the entire blanket via controlled diffusion. Additional features such as the size, the tuck-in flaps and the attuned blower-blanket design make sure the blankets drape perfectly around your patient. It creates a cocoon of warmth, resulting in the maximal heat transfer towards the patient which improves your patient ’s outcome through effective patient warming.
CONTROLLED DIFFUSION
Key Features: • Optimal heat transfer & distribution towards patient • No floating • No disruption of airflow in the surrounding environment • No need for cotton linens The controlled diffusion of air combines a high-volume blower with a low-pressure blanket. The warm air of the high-volume blower is evenly distributed in thewarming blanket due to the aerodynamic attuned design of the warming blankets. The warm air is diffused - quietly and evenly - through the specially designed (permeable) material of the Medkon Warming Blankets on your patient
This technology eliminates individual, high-pressure jets of air that can blow on patients’ skin and cause the blanket to float. The disposable blanket stays in position, keeping warm air on the patient. As a result, there is no disruption of air flow in the surrounding environment and no cooling effect created by wind chill. There is no need to add cotton linens or other drapes to position the Forced Air Warming blankets
The unique Medkon Premium Blankets have an insulat ing top layer. It increases the warming capacit y with at least 10% by reducing radiant heat loss. The Premium Blankets can be used: • Passively: for the pre- and postoperative phase (patient holds the heat during transit periods when not connected to the blower) • Actively: For the pre- and postoperative phase and during surgery
The Mdekon Forced Air Warming unit complies with the latest market expectations. It allows therapy to start within 30 seconds and is comfortable to handle. The warming unit is lightweight, easy to clean and made of impact resistant material. Improve patient outcome through safe, comfortable and smart patient warming. “Medkon Forced Air Warming solution offers a high-quality range of dedicated products to optimise patient warming throughout the entire perioperative process.”
Item Category Dimensions 250mm*300mm*340mm(L×W×H)(not including extrusions) Weight ~5.5kg Wind Force Accuracy:±10 m3/h Level 0: 15 m3/h Level 1: 30 m3/h Level 2: 45 m3/h Level 3:60 m3/h Level 4: 70 m3/h Level 5:85 m3/h Maximum Output Pressure >2600Pa Temperature Range 33℃ to 43℃,at 0.5℃ increments;accuracy±1.5℃ Modes of Operation Natural wind mode、Warming mode Alarms Overheat alarm, Temperature control alarm, High temperature alarm, low temperature alarm, Heater error alarm, Fan error alarm, temperature sensor alarm Power Supply a.c.220V,50Hz,Power: 1800VA(Max.) Safety Class Class I Type BF, IPX1 (Anti dripping sealing equipment) Normal Working Conditions Temperature Humidity Atmospheric Pressure +10℃ to +40℃ 30% to 75% 700hPa to 1060hPa Components Upper case, lower case, fan, air tube, filter, control panel, operation pane