Type | Controller board with RTD PT 100 skin and air temperature sensors |
Model Name/Number | Skin Air type dual control. |
Usage/Application | Hospital |
Material | PCB |
Control Type | PID |
Brand | APS Embedded Systems |
Color | NA |
Height | 190mm |
Width | 116mm |
Control output Type | Relay/SSR |
Input Type | RTD |
Model No. | BW Servo Controller V6.1 |
Heater Power | 650W - 1000W |
Input Voltage | 220V AC |
Temperature Sensor | RTD - PT100 |
Mobile Castors | NA |
Storage Temperature | NA |
Operating Temperature | 25-38 |
Heating element | Ceramic heater |
Suitable For | All types of Infant Warmers |
Operating Voltage | 220V |
Load Capacity | NA |
Bed Capacity | NA |
Air Temperature | 25-38 |
Heater Capacity | 650W |
Control Accuracy | High PID control |
Footprint Size | NA |
Relative Humidity | NA |
Overall Dimensions | NA |
Heater Rotation | NA |
Wheel Diameter | NA |
Heater Wattage | 650W |
Temperature Accuracy | 0.2 Deg |
Effective Area | NA |
Baby Control | NA |
Product Code | BW5V4 |
Drawer Size | NA |
Heater Output | 650W |
Mattress Size | NA |
Max Capacity | NA |
Temperature Resolution | 0.1Deg |
Monitor Tray | NA |
Function | Accurate |
Finish | NA |
Display | large seven segment for actual Skin and Air, LCD for all alerts, Apgar and heater power |
Size | NA |
Voltage | 220V |
Shape | NA |
Frequency | 50Hz |
Feature | PID control, all types of fail safe alarms |
Capacity | 1000W |
Dimensions | NA |
Depth | NA |
Temperature | 25-38 |
Wattage | 650W |
Accuracy | 0.2 deg C |
Humidity | NA |
Footprint | NA |
Irradiance | NA |
Fuse | 5A |
Modes | Skin, Air and manual |
Phase | Single |
Wavelength | NA |
Warranty | 2 years |
Technology | PID |
Resolution | 0.1 deg C |
Country of Origin | Made in India |
OPERATING MODES -
SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.
AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.
MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS
Power fail: Power fail indicator turns ON with sound alert (cannot be muted).
Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.
Heater overload: Heater overload indicator turns ON.
Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.
High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.
Manual mode Time out: Short sound alert and timer flashing on LCD.
Manufactured in Mumbai, Maharashtra, India
We deal in Andhra Pradesh, Arunachal Pradesh, Assam,Bihar, Patna, Chhattisgarh, Raipur, Goa, Panaji, Gujarat, surat, ahemdabad, baroda, Gandhinagar, Haryana, Chandigarh, Himachal Pradesh, Shimla, Jharkhand, Ranchi, Karnataka, Bangalore, Kerala,Thiruvananthapuram, Madhya Pradesh, Bhopal, Maharashtra, Mumbai, Manipur, Imphal, Meghalaya, Shillong, Mizoram, Aizawl, Nagaland, Kohima, Odisha, Bhubaneshwar, Punjab, Chandigarh,Rajasthan, Jaipur, Sikkim, Gangtok, Tamil Nadu, Chennai, Telangana, Hyderabad, Tripura, Agartala, Uttarakhand, Dehradun, Uttar Pradesh, Lucknow, West Bengal
SKU-R_UHNPM4KFESType | Controller board with RTD PT 100 skin and air temperature sensors |
Model Name/Number | Skin Air type dual control. |
Usage/Application | Hospital |
Material | PCB |
Control Type | PID |
Brand | APS Embedded Systems |
Color | NA |
Height | 190mm |
Width | 116mm |
Control output Type | Relay/SSR |
Input Type | RTD |
Model No. | BW Servo Controller V6.1 |
Heater Power | 650W - 1000W |
Input Voltage | 220V AC |
Temperature Sensor | RTD - PT100 |
Mobile Castors | NA |
Storage Temperature | NA |
Operating Temperature | 25-38 |
Heating element | Ceramic heater |
Suitable For | All types of Infant Warmers |
Operating Voltage | 220V |
Load Capacity | NA |
Bed Capacity | NA |
Air Temperature | 25-38 |
Heater Capacity | 650W |
Control Accuracy | High PID control |
Footprint Size | NA |
Relative Humidity | NA |
Overall Dimensions | NA |
Heater Rotation | NA |
Wheel Diameter | NA |
Heater Wattage | 650W |
Temperature Accuracy | 0.2 Deg |
Effective Area | NA |
Baby Control | NA |
Product Code | BW5V4 |
Drawer Size | NA |
Heater Output | 650W |
Mattress Size | NA |
Max Capacity | NA |
Temperature Resolution | 0.1Deg |
Monitor Tray | NA |
Function | Accurate |
Finish | NA |
Display | large seven segment for actual Skin and Air, LCD for all alerts, Apgar and heater power |
Size | NA |
Voltage | 220V |
Shape | NA |
Frequency | 50Hz |
Feature | PID control, all types of fail safe alarms |
Capacity | 1000W |
Dimensions | NA |
Depth | NA |
Temperature | 25-38 |
Wattage | 650W |
Accuracy | 0.2 deg C |
Humidity | NA |
Footprint | NA |
Irradiance | NA |
Fuse | 5A |
Modes | Skin, Air and manual |
Phase | Single |
Wavelength | NA |
Warranty | 2 years |
Technology | PID |
Resolution | 0.1 deg C |
Country of Origin | Made in India |
OPERATING MODES -
SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.
AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.
MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS
Power fail: Power fail indicator turns ON with sound alert (cannot be muted).
Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.
Heater overload: Heater overload indicator turns ON.
Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.
High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.
Manual mode Time out: Short sound alert and timer flashing on LCD.
Manufactured in Mumbai, Maharashtra, India
We deal in Andhra Pradesh, Arunachal Pradesh, Assam,Bihar, Patna, Chhattisgarh, Raipur, Goa, Panaji, Gujarat, surat, ahemdabad, baroda, Gandhinagar, Haryana, Chandigarh, Himachal Pradesh, Shimla, Jharkhand, Ranchi, Karnataka, Bangalore, Kerala,Thiruvananthapuram, Madhya Pradesh, Bhopal, Maharashtra, Mumbai, Manipur, Imphal, Meghalaya, Shillong, Mizoram, Aizawl, Nagaland, Kohima, Odisha, Bhubaneshwar, Punjab, Chandigarh,Rajasthan, Jaipur, Sikkim, Gangtok, Tamil Nadu, Chennai, Telangana, Hyderabad, Tripura, Agartala, Uttarakhand, Dehradun, Uttar Pradesh, Lucknow, West Bengal