Batteries Voltage | 2 x 12 VDC in series |
Current | 120 VAC 2 A maximum , 240 VAC 1 A maximum |
Dimensions | 14.5 in. x 4.3 in. x 22.7 in. |
Model Number | FPA - 1000 - V2 |
Relative Humidity | Up to 95% non - condensing |
Storage Temperature | +14 deg F to +131 deg F (-10 deg C to +55 deg C) |
Voltage | 120 VAC , 60 Hz or 240 VAC , 50 Hz |
Weight | 18.1 lb (8.32 kg) |
Protection Class | IP 30 |
Loop Capacity | 2 |
Brand | Bosch |
Operating Temperature | +32 deg F to +120 deg F (0 deg C to +49 deg C) |
The FPA???1000???UL Analog Addressable Fire Panel is an advanced analogue control panel for small to medium facilities in commercial or public building applications. The FPA???1000???UL combines complete built-in FireAlarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug???inboards. The two integrated NICs can be expanded with remote addressable NAC power boosters and programmed with specific activation patterns. The standard control panel includes one SLC that supports 254 addressable points (254 analogue detectors or modules, or 127 analogue sounder bases in combination with a suitable detector). The control panel is easily expandable with the FPE???1000???SLC Signaling Line Circuit Plug-in Module, doubling the address points to508.
Batteries Voltage | 2 x 12 VDC in series |
Current | 120 VAC 2 A maximum , 240 VAC 1 A maximum |
Dimensions | 14.5 in. x 4.3 in. x 22.7 in. |
Model Number | FPA - 1000 - V2 |
Relative Humidity | Up to 95% non - condensing |
Storage Temperature | +14 deg F to +131 deg F (-10 deg C to +55 deg C) |
Voltage | 120 VAC , 60 Hz or 240 VAC , 50 Hz |
Weight | 18.1 lb (8.32 kg) |
Protection Class | IP 30 |
Loop Capacity | 2 |
Brand | Bosch |
Operating Temperature | +32 deg F to +120 deg F (0 deg C to +49 deg C) |
The FPA???1000???UL Analog Addressable Fire Panel is an advanced analogue control panel for small to medium facilities in commercial or public building applications. The FPA???1000???UL combines complete built-in FireAlarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug???inboards. The two integrated NICs can be expanded with remote addressable NAC power boosters and programmed with specific activation patterns. The standard control panel includes one SLC that supports 254 addressable points (254 analogue detectors or modules, or 127 analogue sounder bases in combination with a suitable detector). The control panel is easily expandable with the FPE???1000???SLC Signaling Line Circuit Plug-in Module, doubling the address points to508.