Brand | BMC |
Model | BMC Y30T |
Pressure Range (cm H2O) | 4-30 cm H2O |
Operating Mode | CPAP, S, S / T, T operating modes |
Ramp Rate | 0-60 Minutes |
Type | Auto BiPAP, Manual CPAP, BiPAP, Auto CPAP |
Warranty | 1 YEAR |
Weight | 1.3 kg |
Dimensions | 36 x 23 x 28 cm |
Data Storage Capacity | SD Card (8 GB) |
General Features
• Target Tidal Volume: Pressure Support Automatically Adjusts According to Target Tidal Volume as to Improve Hypoventilation. • Real Time Monitoring Includes Pressure, Flow, Expiratory Tidal Volume (Vte), Respiratory Rate (RR), Minute Ventilation (MV), Leak, Inspiration Time (Ti), Spo2* and Pulse Rate (PR)* • Ventilation Efficacy: Advanced Leakage Compensation Promises Adequate Volume Support. Ti Control, I/E Sense and Rise Time Guarantee Better Ventilation Synchronization • CPAP, S, S / T, T Operating Modes • Simple, Reliable, Sensitive, Quickly Synchronized with The Patient • 8-Step Inhalation Exhalation Triggers • Build Quality Conforms to German Standards • 3.5" Color LCD display • Monitoring Vt, Res Rate, Min Vent, Leak. Alarms in All Respects • 5-Step Adjustment of The Humidifier • Display of The Key Parameters of Therapy in The Online Mode • High-Quality Body and Humidifier Materials • Adjusting the Inhalation-Exhalation Pressure, Inhalation Time (0.5-3 Seconds) and Respiration Rate MC RESmart BiPAP Y-30T
Technical Specification
• Dimensions: 170 mm x 180 mm x 118 mm, or 290 mm x 180 mm x 134 mm (With the Humidifier) • Weight: 1.5 kg or 2.5Kg (With the Humidifier) • Main Device Power to Humidifier: 24 V 1.5 A • Product Use, Transport and Storage Operation • Degree of Protection Against Ingress of Water: IP22 Temperature: 5°C to 35°C (41 F to 95'F) -25°C to 70°C (-13 F to 158F) • Tube Length: 6 ft. (1.83 m) Humidity: 15% to 93% Non-Condensing 15% to 93% Non-Condensing • CPAP Mode: 4.0 ~ 20.0 hPa Atmospheric Pressure: 760 to 1060hPa 760 to 1060hPa • Mode of Operation: Continuous • Work Mode: CPAP, S, Auto S, Auto CPAP, S/T, T • Static Pressure Stability: + 0.5hPa • Type of Protection Against Electric Shock: Class II Equipment • Pressure Display Accuracy: + (0.8 ha† 4%) • AC Power Consumption: 100 - 240 V ~ 2 - 1 A, 50 / 60 Hz •Pulse Rate Range: 40 to 240 Bpm, Margin of Error: $1% • Main Device Offer to USB Communications Port: 5 V 2.0 A • Wavelengths Red: 663 Nano-meters, Infrared: 890 Nano-meters • Ramp: The Ramp Time Ranges From 0 To 60 Minutes • Maximal Optical Output Power: < 1.5 mw Maximum Average • SD Card: The SD Card can Record Patient Data and Fault Information • Degree of Protection Against Electric Shock: Type BF Applied Parts • The Form and the Dimensions of the Patient Connection Port: The 22 mm Conical Air Outlet Complies with ISO 5356-1 • RESmart GII BPAP System Y / U Series User Manual V2.1: 6 / 42 • Sound Pressure Level: < 30 dB, When the Device is Working at the Pressure of 10hPa • Sound Power Level: < 38 dB, When the Device is Working at the Pressure of 1 ha • Maximum Flow: Test Pressures (ha) 4 Measured Pressure at the Patient Connection Port (ha) 3 Average Flow at the Patient Connection Port (L/min) 93.2 97.6 15 14 98.1 20 19 98.5 25 24 99.1 • Sp02 Range: 0 ~ 100%, The Margin of Error for SpO2 Between 70% and 100% is ‡ 3% No Strict Accuracy Requirements for Sp02 Below 70% • Pressure Range: 4 to 30hPa (in 0.5ha Increments) Under Single Fault Conditions, § 30 hPa for PAP Mode, ≤ 40 ha for the Rest Modes
Brand | BMC |
Model | BMC Y30T |
Pressure Range (cm H2O) | 4-30 cm H2O |
Operating Mode | CPAP, S, S / T, T operating modes |
Ramp Rate | 0-60 Minutes |
Type | Auto BiPAP, Manual CPAP, BiPAP, Auto CPAP |
Warranty | 1 YEAR |
Weight | 1.3 kg |
Dimensions | 36 x 23 x 28 cm |
Data Storage Capacity | SD Card (8 GB) |
General Features
• Target Tidal Volume: Pressure Support Automatically Adjusts According to Target Tidal Volume as to Improve Hypoventilation. • Real Time Monitoring Includes Pressure, Flow, Expiratory Tidal Volume (Vte), Respiratory Rate (RR), Minute Ventilation (MV), Leak, Inspiration Time (Ti), Spo2* and Pulse Rate (PR)* • Ventilation Efficacy: Advanced Leakage Compensation Promises Adequate Volume Support. Ti Control, I/E Sense and Rise Time Guarantee Better Ventilation Synchronization • CPAP, S, S / T, T Operating Modes • Simple, Reliable, Sensitive, Quickly Synchronized with The Patient • 8-Step Inhalation Exhalation Triggers • Build Quality Conforms to German Standards • 3.5" Color LCD display • Monitoring Vt, Res Rate, Min Vent, Leak. Alarms in All Respects • 5-Step Adjustment of The Humidifier • Display of The Key Parameters of Therapy in The Online Mode • High-Quality Body and Humidifier Materials • Adjusting the Inhalation-Exhalation Pressure, Inhalation Time (0.5-3 Seconds) and Respiration Rate MC RESmart BiPAP Y-30T
Technical Specification
• Dimensions: 170 mm x 180 mm x 118 mm, or 290 mm x 180 mm x 134 mm (With the Humidifier) • Weight: 1.5 kg or 2.5Kg (With the Humidifier) • Main Device Power to Humidifier: 24 V 1.5 A • Product Use, Transport and Storage Operation • Degree of Protection Against Ingress of Water: IP22 Temperature: 5°C to 35°C (41 F to 95'F) -25°C to 70°C (-13 F to 158F) • Tube Length: 6 ft. (1.83 m) Humidity: 15% to 93% Non-Condensing 15% to 93% Non-Condensing • CPAP Mode: 4.0 ~ 20.0 hPa Atmospheric Pressure: 760 to 1060hPa 760 to 1060hPa • Mode of Operation: Continuous • Work Mode: CPAP, S, Auto S, Auto CPAP, S/T, T • Static Pressure Stability: + 0.5hPa • Type of Protection Against Electric Shock: Class II Equipment • Pressure Display Accuracy: + (0.8 ha† 4%) • AC Power Consumption: 100 - 240 V ~ 2 - 1 A, 50 / 60 Hz •Pulse Rate Range: 40 to 240 Bpm, Margin of Error: $1% • Main Device Offer to USB Communications Port: 5 V 2.0 A • Wavelengths Red: 663 Nano-meters, Infrared: 890 Nano-meters • Ramp: The Ramp Time Ranges From 0 To 60 Minutes • Maximal Optical Output Power: < 1.5 mw Maximum Average • SD Card: The SD Card can Record Patient Data and Fault Information • Degree of Protection Against Electric Shock: Type BF Applied Parts • The Form and the Dimensions of the Patient Connection Port: The 22 mm Conical Air Outlet Complies with ISO 5356-1 • RESmart GII BPAP System Y / U Series User Manual V2.1: 6 / 42 • Sound Pressure Level: < 30 dB, When the Device is Working at the Pressure of 10hPa • Sound Power Level: < 38 dB, When the Device is Working at the Pressure of 1 ha • Maximum Flow: Test Pressures (ha) 4 Measured Pressure at the Patient Connection Port (ha) 3 Average Flow at the Patient Connection Port (L/min) 93.2 97.6 15 14 98.1 20 19 98.5 25 24 99.1 • Sp02 Range: 0 ~ 100%, The Margin of Error for SpO2 Between 70% and 100% is ‡ 3% No Strict Accuracy Requirements for Sp02 Below 70% • Pressure Range: 4 to 30hPa (in 0.5ha Increments) Under Single Fault Conditions, § 30 hPa for PAP Mode, ≤ 40 ha for the Rest Modes